Positron emission tomography/computed tomography for diagnosis of prosthetic valve endocarditis – Increased valvular 18F-fluorodeoxyglucose uptake as a novel major criterion.

November 8, 2015 at 7:04 pm

J Am Coll Cardiol. 2013 Jun 11;61(23):2374-82.

Saby L1, Laas O, Habib G, Cammilleri S, Mancini J, Tessonnier L, Casalta JP, Gouriet F, Riberi A, Avierinos JF, Collart F, Mundler O, Raoult D, Thuny F.

Author information

1Département de Cardiologie, Hôpital de la Timone, AP-HM, Aix-Marseille Université, Marseille, France.

Abstract

OBJECTIVES:

This study sought to determine the value of (18)F-fluorodeoxyglucose positron emission tomography/computed tomography ((18)F-FDG PET/CT) for diagnosing prosthetic valve endocarditis (PVE).

BACKGROUND:

The diagnosis of PVE remains challenging. In PVE cases, initial echocardiography is normal or inconclusive in almost 30%, leading to a decreased diagnostic accuracy for the modified Duke criteria.

METHODS:

We prospectively studied 72 consecutive patients suspected of having PVE. All of the patients were subjected to clinical, microbiological, and echocardiographic evaluation. Cardiac PET/CT was performed at admission. The final diagnosis was defined according to the clinical and/or pathological modified Duke criteria determined during a 3-month follow-up.

RESULTS:

Thirty-six patients (50%) exhibited abnormal FDG uptake around the site of the prosthetic valve. The sensitivity, specificity, positive predictive value, negative predictive value, and global accuracy were as follows (95% confidence interval): 73% (54% to 87%), 80% (56% to 93%), 85% (64% to 95%), 67% (45% to 84%), and 76% (63% to 86%), respectively. Adding abnormal FDG uptake around the prosthetic valve as a new major criterion significantly increased the sensitivity of the modified Duke criteria at admission (70% [52% to 83%] vs. 97% [83% to 99%], p = 0.008). This result was due to a significant reduction (p < 0.0001) in the number of possible PVE cases from 40 (56%) to 23 (32%).

CONCLUSIONS:

The use of (18)F-FDG PET/CT was helpful for diagnosing PVE. The results of this study support the addition of abnormal FDG uptake as a novel major criterion for PVE.

FULL TEXT

http://www.sciencedirect.com/science/article/pii/S0735109713014113

PDF

http://ac.els-cdn.com/S0735109713014113/1-s2.0-S0735109713014113-main.pdf?_tid=fad31e9a-78dc-11e5-9686-00000aacb360&acdnat=1445532800_52899fb4737aca2a22f140e2cec12eb3

 

Advertisements

Entry filed under: Infecciones cardio-vasculares, Metodos diagnosticos, Sepsis, Update.

Complete and partly unexpected diagnostic findings at 18F-FDG-PET/CT scanning in patients with suspected prosthetic valve endocarditis. Adding or selecting imaging modalities for incremental diagnosis – A case study of ¹FDG PET/CT in prosthetic valve endocarditis.


Calendar

November 2015
M T W T F S S
« Oct   Dec »
 1
2345678
9101112131415
16171819202122
23242526272829
30  

Most Recent Posts


%d bloggers like this: